Skip to menu

NCM-I SERIES

NCM-I-SERIES - Closed Chamber Type Medium Pressure Inline UV System

  1. Few powerful medium pressure (MP) UV lamps can serve large size treatment
  2. aadapted MP lamp that is stronger and produces wider range of UV spectrum than low pressure UV lamps
  3. Implemented automatic sleeve wiper mechanism, UV monitoring, energy save mode, remote control mode, various other system monitoring, etc. for easy maintenance
  4. Various applications including disinfection & TOC removal for ultra pure water, drinking water disinfection, de-chlorination, de-ozonization, brewery, beverage, mineral water, swimming pool, etc.

Standard Specification

Module Specification  
Material Stst 316L, (Option : Electropolishing)
Lamp Type / Input Power Per Lamp Medium Pressure UV lamp / 0.5kW -20kW
Cleaning System (if applicable) Motor driven automatic wiper mechanism
Operating Water Temperature 5℃~65℃
Connections P16, DN, ANSI150, JIS, KS
Working / Max. operation pressure 10bar / 15bar
Enclosure Specification  
Material RAL 7032, Mid steel (Option : STS304)
Protection Rating IP54 / NEMA 4X
System Control Panel (SCP)  
Controller PLC
Voltage / Frequency 220V~480V / 50/60Hz
Operating Temperature 0℃~50℃
Power Supply Panel (PSP)  
Ballast Type Variable output electronic ballast/ magnetic ballast

NCM-I SERIES

NCM-I SERIES - Model Chart

* Based on discharge water from wastewater treatment plants (T10 : 65%)
No. Model Capacity (Ton/day) Lamp Input x Lamp Qty’ In/Out Dia (DN)
1 NCM-IA125-E1 1000 1.5Kw 125
2 NCM-IA125-E2 1800 1.5Kw 125
3 NCM-IA200-E3 2400 1.5Kw 200
4 NCM-IA200-E4 4000 1.5Kw x 3 200
5 NCM-IA200-E5 5400 3.5Kw x 4 200
6 NCM-IA200-E6 8000 3.5Kw x 6 200
7 NCM-IA300-F6 10000 1.6Kw x 6 300
8 NCM-A300-F8 13000 1.6Kw x 8 300
9 NCM-IA350-F2/J4 16000 1.6Kw x 2 / 2.65Kw x 4 350
10 NCM-IA350-F4/J4 20000 1.6Kw x 4 / 2.65Kw x 4 350
11 NCM-IA350-J8 22000 2.65Kw x 8 350
12 NCM-IA350-J8 26000 2.65Kw x 8 500
13 NCM-IA500-J4/M4 36000 2.65Kw x 4 / 3.9Kw x 4 500
14 NCM-IA500-M8 40000 3.9Kw x 8 500
- Average dose : 25mJ/cm2

Note:
1. 1 m3/d converts to 1 ton/d. 1 m3 converts to 264.172 US liquid gallon.
2. Inlet/Outlet diameter can be customized.

Galllary

Zhenzou(China) Largest MP UV System