Skip to menu

NCL-SERIES

NCL-M SERIES – Closed Chamber Type Low Pressure Motorized UV System

  1. Low installation and operation cost
  2. Adopted high efficiency LPHO / amalgam UV lamp
  3. Cost efficient and easy maintenance with automatic wiper mechanism as a standard option
  4. Applicable for small to medium size plants
  5. Pre-wired cable leads for control panel and chamber using onetouch connector
NCL-M SERIES
Model NCL-M NCL-M(A)-AML
Cleaning System
Motor driven automatic wiper mechanism
Lamp, Input Power
Standard LP, 40 - 90W
LPHO / amalgam lamp, 120 - 320W
Application Small size wastewater disinfection, portable water treatment, pool, aquarium, etc. Medium size wastewater disinfection, overall industry

NCL-M SERIES - Model Chart

* Based on discharge water from wastewater treatment plants (T10 : 65%)
No. NCL SERIES-Model Capacity (Ton/day) Chamber Dia In/Out Dia Lamp Input Lamp Qty'
1 NCL-M125-B1 70 125A 80A 90W 1
2 NCL-M125-C1 120 125A 80A 120W 1
3 NCL-M150-A4 160 150A 100A 41W 4
4 NCL-M150-B4 300 150A 100A 90W 4
5 NCL-M200-B6 450 200A 150A 90W 6
6 NCL-M200-C6 720 200A 150A 120W 6
7 NCL-M200-D4 1800 200A 150A 240W 4
8 NCL-M250-D6 2700 250A 200A 240W 6
9 NCL-M250-D8 3600 250A 200A 240W 8
10 NCL-M300-E8 4500 300A 250A 320W 8

Note:
1. 1 m3/d converts to 1 ton/d. 1 m3 converts to 264.172 US liquid gallon.
2. Inlet/Outlet diameter can be customized.

Gallary

JeJu-Island Aquarium